200 800.292.2737 |
[email protected] | aymcdonald.com A.Y. McDonald American Meter Regulators 11/25 Regulators 3000 Series Industrial Regulator 3000 Series Regulator Capacity Data 2” 3000 SERIES REGULATOR SCFH (SCMH m3/h) 0.60 specific gravity gas at 60 °F and 14.7PSIA 2” 3000 SERIES REGULATOR - HIGH PRESSURE SCFH (SCMH m3/h) 0.60 specific gravity gas at 60 °F and 14.7PSIA Spring No. 70157P025 70157P027 70157P006 70157P017 70157P024 Inlet Pressure 2" W.C. .5% Droop 4" W.C. 1% Droop 6" W.C. 1% Droop 9" W.C. 1% Droop 12" W.C. 2% Droop 16" W.C. 2% Droop 20" W.C. 2% Droop 24" W.C. 2.5% Droop 28" W.C. 3% Droop 42" W.C. 4% Droop 56" W.C. 5% Droop 8" WC (20 mbar) 5,000 (198) 4,000 (113) 2,300 (65.1) 14" WC (35 mbar) 7,000 (198) 6,000 (170) 5,000 (142) 2,800 (79.3) 2,000 (56.6) 21" WC (52 mbar) 8,000 (227) 8,000 (227) 7,600 (215) 4,000 (113) 5,800 (164) 2,200 (62.3) 1 PSIG (69 mbar) 10,000 (283) 8,500 (241) 9,200 (261) 5,000 (142) 6,600 (187) 4,000 (113) 2,400 (68.0) 2,100 (59.5) 1.5 PSIG (103 mbar) 12,500 (354) 11,500 (326) 12,500 (354) 7,400 (210) 10,000 (283) 6,500 (184) 5,000 (142) 5,000 (142) 3,600 (102) 2 PSIG (138 mbar) 15,000 (425) 13,500 (382) 14,800 (419) 10,500 (297) 13,000 (368) 8,500 (241) 6,500 (184) 7,000 (198) 7,000 (198) 5,000 (142) 3 PSIG (207 mbar) 18,000 (510) 16,500 (467) 18,500 (524) 16,000 (453) 17,500 (496) 11,500 (326) 9,500 (269) 9,500 (269) 10,000 (283) 8,200 (232) 6,100 (173) 5 PSIG (345 mbar) 18,500 (524) 19,000 (538) 24,200 (685) 24,000 (680) 24,000 (680) 14,500 (411) 13,000 (368) 13,500 (382) 14,500 (411) 13,000 (368) 12,000 (340) 10 PSIG (690 mbar) 19,000 (538) 21,000 (595) 21,800 (617) 20,000 (566) 22,000 (623) 21,000 (595) 20,500 (580) 21,000 (595) 20,500 (580) 20,800 (589) 20,500 (580) 15 PSIG (1.03 Bar) 19,500 (552) 24,000 (680) 26,000 (736) 27,000 (736) 30,000 (849) 29,000 (821) 25,500 (722) 25,000 (708) 27,500 (779) 21,500 (609) 22,000 (623) 20 PSIG (1.38 Bar) 17,500 (496) 25,000 (708) 26,000 (736) 26,000 (736) 24,000 (680) 25,000 (708) 26,000 (736) 22,000 (623) 24,000 (680) 25 PSIG (1.72 Bar) 15,500 (439) 22,000 (623) 25,000 (708) 24,000 (680) 24,000 (680) 24,000 (680) 25,000 (708) 23,000 (651) 25,000 (708) 30 PSIG (2.07 Bar) 14,000 (396) 20,000 (566) 24,000 (680) 22,000 (623) 22,000 (623) 22,000 (623) 23,000 (651) 23,000 (651) 24,500 (694) Spring No. 71411P021 71411P022 71411P044 71411P023 71411P021 Inlet Pressure 2" W.C. .5% Droop 4" W.C. 1% Droop 6" W.C. 1% Droop 9" W.C. 1% Droop 12" W.C. 2% Droop 16" W.C. 2% Droop 20" W.C. 2% Droop 24" W.C. 2.5% Droop 28" W.C. 3% Droop 42" W.C. 4% Droop 56" W.C. 5% Droop 3 PSIG (207 mbar) 3,900 (110) 2,400 (68.0) 1,600 (45.3) 4 PSIG (276 mbar) 4,900 (139) 4,600 (130) 3,500 (99.1) 2,600 (73.6) 2,000 (56.6) 5 PSIG (345 mbar) 9,600 (272) 8,500 (241) 4,800 (136) 5,200 (147) 4,500 (127) 2,300 (65.1) 6 PSIG (414 mbar) 10,300 (292) 9,700 (275) 5,400 (153) 5,600 (159) 6,700 (190) 4,100 (116) 7 PSIG (483 mbar) 14,200 (402) 12,600 (357) 6,100 (173) 6,400 (181) 7,100 (201) 7,300 (207) 4,600 (130) 8 PSIG (552 mbar) 16,200 (459) 16,000 (453) 6,700 (190) 7,900 (224) 9,000 (255) 9,200 (261) 7,300 (207) 6,000 (170) 9 PSIG (621 mbar) 17,900 (507) 18,400 (521) 7,500 (212) 9,300 (263) 10,400 (294) 11,100 (314) 8,300 (235) 8,500 (241) 5,100 (144) 10 PSIG (690 mbar) 20,600 (583) 21,400 (610) 8,500 (241) 9,700 (275) 11,500 (326) 12,200 (345) 10,600 (300) 10,500 (297) 4,900 (138) 5,000 (142) 15 PSIG (1.03 Bar) 29,500 (835) 39,900 (1,130) 9,200 (261) 18,200 (515) 18,500 (524) 19,000 (538) 16,800 (476) 17,800 (504) 15,400 (436) 15,700 (445) 15,800 (447) 20 PSIG (1.38 Bar) 25,100 (711) 28,600 (810) 36,700 (1,039) 47,300 (1,339) 47,200 (1,337) 46,700 (1,323) 28,900 (818) 29,800 (844) 24,000 (680) 24,300 (688) 26,500 (750) 25 PSIG (1.72 Bar) 23,700 (671) 27,900 (790) 33,600 (951) 36,600 (1,036) 41,300 (1,169) 51,900 (1,470) 57,900 (1,640) 54,200 (1,535) 41,000 (1,161) 39,300 (1,113) 36,900 (1,045) 30 PSIG (2.07 Bar) 23,400 (663) 27,000 (765) 31,100 (881) 33,400 (946) 38,800 (1,099) 44,500 (1,260) 52,300 (1,481) 66,500 (1,883) 64,400 (1,824) 64,400 (1,824) 61,600 (1,744) For optimum performance, use with inlet pressures above line For optimum performance, use with inlet pressures above line